Skip to content
Back to Device & Firmware Assessments

Device & Firmware Assessments

Open it up, measure it, and compare it with what it's supposed to be.

A device assessment in the OASIS lab looks at how a unit is built, what's on the board, what the firmware says and what the materials are, against whatever reference you can give us. The report records what we found, how we checked it, and what's still open.

The work

The device against the reference

A part that shouldn't be there, a supplier who can't explain a discrepancy, a repair you didn't authorize: these are the questions that bring a device to the bench. We compare the unit with its documentation, its sourcing records or a reference unit, and explain the differences we find.

Before we accept the device we agree what we can access, what we'll compare against and which methods we'll use. The toolkit includes stereo microscopy, component research, bench electrical measurements, thermal imaging and analysis of any firmware we can read. For material questions, FTIR spectroscopy and wet-lab work are available when the sample and the method suit each other.

OASIS lab

Equipment used in device assessments

OASIS combines an electronics bench with a full wet lab. Microscopy, electrical measurements, thermal imaging and material analysis can help explain differences that a visual inspection alone leaves open.

Generated view of an electronics bench with a stereo microscope, an opened device, an oscilloscope, a bench power supply and a thermal camera.

Electronics bench

Stereo microscopy, controlled power, oscilloscope measurements and thermal imaging.

Generated view of a materials workspace with an FTIR spectrometer and polymer samples, beside a separate wet-lab bench and fume hood.

Materials and wet lab

FTIR spectroscopy, sample preparation and chemical analysis chosen for the material question.

AI-generated illustrations of the equipment and methods described here, not photographs of the OASIS facilities.

The process

How a device assessment runs

  1. Agree the question and the permission

    Which device, what decision rides on it, what we're authorized to do and how the unit must be handled. Opening, powering, readout and anything destructive are each agreed before they happen.

  2. Record the starting condition

    Identifiers, accessories, visible condition, relevant history. We photograph the device before it's opened and keep a log of everything we do to it from there.

  3. Examine and compare

    We run the agreed methods and compare the results with the documentation, reference units or files available. The setup, the differences and the areas we couldn't reach all go in the record.

  4. Explain the findings

    Each conclusion points back to a recorded observation and a reference. You get the agreed artifacts, the open questions and the practical next steps, and the device goes back (or gets disposed of) the way we agreed.

Methods & equipment

Methods and equipment

The device and the question pick the methods. What we can access, the condition of the unit and the references available decide what can be examined and compared.

Exterior, tool marks and board inspection

Stereo microscopy

We record the enclosure, labels, seals, fasteners and connectors before opening the unit. A stereo microscope helps us inspect accessible board areas, component markings, solder joints and wear around fasteners or clips. Images include the surrounding area so a detail can be located on the device.

Scratches, solder residue or a disturbed fastener can come from assembly, repair or later handling. We compare them with the device history and a suitable reference where available. A mark alone does not establish who made it, when or why.

In the report: Annotated photographs and a record of visible differences, their locations and areas that could not be inspected.

Component identity and authenticity

Markings, documentation and sourcing records

We compare accessible package markings, part numbers, board revisions and date or lot codes with manufacturer documentation, available bills of materials and reference units. Purchasing records and the supplier chain help establish where a part came from.

Inconsistent codes, altered surfaces or unexpected parts deserve a closer look. Matching markings alone do not authenticate a part; counterfeits can reproduce them. We distinguish a documented match, a discrepancy and a question that needs manufacturer confirmation or a specialist test.

In the report: An inventory of the examined parts, the comparison sources and any unresolved authenticity questions.

Powered checks and thermal observations

Bench power supplies, oscilloscopes and thermal imaging

When powered testing is appropriate, we first confirm the supply requirements, grounding, probe limits and device condition. Current-limited bench power and suitable oscilloscope probes can help us examine accessible supply rails, start-up behavior, ripple or other agreed signals. We record the load conditions and measurement setup.

Infrared thermal imaging adds context to heat patterns under the agreed operating conditions. Surface emissivity and reflections affect the reading, so an apparent hot spot needs to be checked in context. These measurements describe the tested conditions; electrical safety or product certification requires its own scope.

In the report: Selected measurements or traces, test conditions and an explanation of any differences that matter to the question.

Firmware and configuration

Authorized readout and file analysis

We start with accessible sources: a vendor update image, an authorized device export or a readout whose interface and tooling have been confirmed. The record identifies the source, device and board identifiers, reported version, acquisition method and hashes of the acquired files.

Where an image is readable, static analysis can examine configuration and included components, compare documented references, or review update and boot protections. Device-specific regions may differ legitimately. Encryption, locked interfaces and incomplete images can limit what is visible. A hash lets us check whether file bytes have changed; it does not establish that firmware is trustworthy.

In the report: A file and hash manifest, the comparisons performed, findings from the agreed analysis and any unreadable or unexamined areas.

Plastic housings and material analysis

FTIR spectroscopy and wet-lab preparation

An enclosure marked PC, ABS or PC+ABS names a polymer family or blend. We record those markings, visible seams, surface changes and damage, then compare them with available drawings, specifications or reference parts. A molded label and the look or feel of a plastic do not establish its exact grade, fillers or formulation.

For chemical identification, FTIR spectroscopy can compare a sample’s infrared spectrum with suitable reference material or a spectral library. Our wet lab supports scoped sample preparation and chemical analysis when inspection alone cannot answer the material question. Sampling and methods are agreed before material is removed or treated.

Coatings, contamination and mixed materials can affect the result and may need separate sampling. We explain which part of the sample was measured and how well the reference fits. Thermal imaging describes heat patterns; FTIR examines infrared absorption associated with the material. Neither a surface spectrum nor a molded label establishes every ingredient in a finished part.

In the report: The declared material type, sampling record, agreed analytical results and reference comparisons, with limits on material identification.

Deliverables

What you receive.

  1. A technical report connecting each finding to the observations and comparison material.

  2. Photographs, component records, measurements, traces or a firmware-file manifest, according to the methods used.

  3. A record of the received condition, authorized work, methods, references and changes made during the assessment.

  4. Unresolved questions, limits on the conclusions and practical next steps for your engineering or supplier discussion.

What you get depends on what we did. A visual inspection doesn't produce the same artifacts as a firmware readout or a powered test.

Before we begin

Talk to us before you ship anything.

Tell us the device type, the technical question, the relevant history, any reference units or files you have, and any data-sensitivity or handling constraints. Let us know if the unit has to keep working afterward, and whether opening it voids a warranty or breaks a seal.

The contact form is for a high-level summary. Authorization, transport, storage, sensitive files, any destructive steps and the return or disposal plan are agreed separately before anything is sent.

Feasibility and scope first

Pricing follows the methods and deliverables we agree on. We can give you a date once we understand the device, the access it needs and the constraints.

Scope and limitations

Reading the results

The report keeps direct observations, our interpretation and the unanswered questions in separate places. An unexpected part or a firmware difference needs context before it means anything. And finding nothing wrong in the areas we examined is not the same as proving the device is clean.

If your decision needs specialist imaging, destructive chip analysis, certified material identification or a formal handling standard, say so during scoping. We'll tell you what we can do and what needs a different method or a different lab.

Questions

Common questions

Will the device still work after a teardown?

That depends on its construction and the agreed methods. We discuss seals, adhesives, fragile connectors, sampling and return requirements before work starts. Any destructive step requires prior agreement; continued operation cannot be assumed for every device.

What makes a useful reference?

A reference unit with a documented source, manufacturer documentation, a bill of materials, purchasing records or a firmware image for the correct hardware revision can all help. We record where a reference came from and whether differences in revision or configuration affect the comparison.

Does this certify that a part is genuine or a device is safe?

The report states what the selected checks establish. It is not a blanket authenticity or safety certificate. Manufacturer authentication, accredited testing and suitability for a formal proceeding must be addressed as specific requirements before accepting the work.

Next step

Start with the device and the question.

Describe what's bothering you about it and any reference material you have. We'll confirm the methods and the handling before the device is sent.

Discuss a device assessment